|
AQ100
Air Quality Measurements
Measure Indoor Air Quality with the
KIMO Portable Series
The Basic: the AQ100
Measure CO2 levels and ambient temperature
with the AQ100.
• Remote probe with 1 meter cable.
• Displays minimum and maximum.
|
|
|
|
AQ200
The Professional Tool: the AQ200
Measure CO2 and CO levels, humidity and temperature.
• Data logging for your reports.
• Wireless probe and data transfert.
• Many probes and modules are available: CO,
CO2, humidity, temperature, ambient
conditions
and
omnidirectional air velocity
probe.
• Selection of units (temperature)
• Minimum and maximum values
• HOLD function
• Adjustable automatic shut-off
• Adjustable backlight
|
|
|
|
|
CO 100
CO Detector
• Easy to use
• Large backlight display
• Indication of CO in ppm and temperature in °C
• Display of CO max
• Two adjustable alarm thresholds
|
|
|
|
DBM 610
Air Flow Meter
• Sturdy, lightweight and easy to handle.
• Measuring range from 40 to 3500 m³/h,
25 to 2000 pi³/min, ±2500 Pa, ±10 inH2O.
• Simultaneous display of airflow
and temperature.
• Automatic airflow direction (extraction
or air blast).
• DBM610 airflow meter comes in standard with
a 610 x 610 mm hood. 4 others hoods are
available as options. Hoods are airtight and
have a transparent part on each side allowing
the user to see through the vent and ensure
that the hood is in a good position. The rods,
made of fiberglass, make for a sturdier hood.
• The flow area is attached to the base and
allows the measurement on 48 points, all over
the surface of the flow area.
• Measurement is performed using a differential
pressure sensor, calibrated and compensated
in atmospheric pressure and in temperature.
• Removable measuring unit (micromanometer
function).
• Data processing on computer with USB port.
• Different languages available.
|
|
|
|
DS 200
Noise dosimeter
Individual noise dosimeter
Combined with data software LDS300, the DS200 instrument allows the user to determine the sound exposure level at a workstation in compliance with Statutory Instrument and effective standards : 2003/10/CE Directive, NF S 31-084 and ISO 9612:2009 standards.
• Noise exposure at workstation
according to:
station (automatic measurement)
task
function
• Setting up of HEG
(Homogeneous Exposure Group):
Integration of measurement uncertainty
due to principle and instrument.
• Calculation of exposure levels in case
of using PPE
(Personal Protective Equipment)
as per SNR and HML methods
DS200 dosimeter is supplied with LDS 23 software allowing data visualization and printing of measurement report.
|
|
|
|
|
DS 300
Noise dosimeter
Individual noise dosimeter
The DS300 instrument allows the user to determine the sound exposure level at a workstation in compliance with Statutory Instrument and effective standards : 2003/10/CE Directive and NF S 31-084.
• Only one extended dynamic range of 100 dB:
40-140 dB
• Conventional integrating-averaging
hand sound level meter mode
• Frequency analysis by octave bands from
63 Hz to 8 kHz, which facilitates the
selection of ear protections
• Two-channel measurement* allowing the
optimal detection of exposure in the case
of skewness of the sound environment
(right ear/left ear).
• Audio recording* on threshold exceeding,
peaks or short LAeq allows the identification
and the recognition of sound sources.
DS300 dosimeter is supplied with LDS23 software allowing data visualization and printing of measurement report.
|
|
|
|
|
FG 100
Gas Leak Detector
• Easy to use
• Large backlight display
• Indication of gas leaking in ppm or in %VOL
or in %LEL
• Detection of gas such as methane (CH4),
LPG (isopropanol and isobutane) and other
combustible gas (hydrocarbon)
• Display of the concentration of measured gas
in ppm, %VOL and % LEL
• Flexible probe with semiconductor gas sensor
• Digital display
|
|
|
|
HM 100
Pin moisture meter
• Indication of humidity percentage for
4 types of different materials:
Hardwood
Softwood
Concrete and plaster
Bricks
• Minimum and maximum values for each
type of material
• Protection cap and auto-test
|
|
|
|
|
KIRAY 100
Infrared thermometer
Infrared thermometer KIRAY 100 with dual laser sighting is a key tool to diagnose, inspect and check any temperature, with the advantage of using “no-contact” technology. You can
safely measure surface temperatures of hot objects, dangerous or difficult to access. Perfect tool to take temperature in a house, a garage, a workshop, an office, a car, a kitchen etc.
|
|
|
|
|
KIRAY 200
Infrared thermometer
Infrared thermometer KIRAY 200 is an infrared thermometer used
to diagnose, inspect and check any temperature. Thanks to its
elaborated optical system, it allows an easy and accurate
measurement of little distant targets. KIRAY 200 instrument has
an internal memory which can save up to 20 measurements.
|
|
|
|
|
KIRAY 300
Infrared thermometer
Infrared thermometer Kiray 300 is a thermometer used to diagnose, inspect and check any temperature. Thanks to its elaborated optical system with a dual laser sighting, it allows easy
and accurate measurements of little distant targets. The KIRAY
300 instrument has an internal memory which can save up to 100
measurements. Compatible with thermocouple K probe.
|
|
|
|
|
LV 120 - LV 130
Vane Probe Thermo-Anemometers
• Selection of units
(air velocity, air flow and temperature)
• HOLD function
• Minimum and maximum values
• Automatic average
• Airflow calculation
• Airflow calculation with cone
• Adjustable automatic shut-off
• Adjustable backlight
• Detection of flow direction
LV 130 - Ø 100 mm vane probe – Fixed and
rotating. Vane probe rotation: +180° / -90° increments of 90°
LV 120 - Ø 100 mm vane probe – fixed
and non-rotating
|
|
|
|
|
LX 100
LUXMETER
The LX100 hand-held luxmeter, self-contained and automatic is specially designed for illuminance measurement.
• Illuminance measurement in lux or in foot-candelas for illuminance levels below 10 lux, with 0.1 lux calculation accuracy and with 1% accuracy beyond 150000 lux.
• Instantaneous measurement, display
illuminance for local measurements.
• With timed measurement:
Illuminance min/max values display.
Illuminance averaged value calculation.
• With relative illuminance function:
Allows a relative measurement to a reference
point for the quantification of a luminous
contribution or an illuminance decrease.
• With hold function:
Allows to avoid illuminance noise or to save
on screen local measurement.
Measurement saving when unexpected
power cut occurs.
Sensing element in silicon photodiode, with spectral responsivity in accordance with photonic curve (CIE).
|
|
|
|
LX 200
Luxmeter
The LX200 hand-held luxmeter, self-contained and automatic, is specially designed for illuminance measurement. It allows storage of datasets for processing on a computer via the LLX200 software.
• Instantaneous illuminance
Displaying of instantaneous / maximum /
minimum values.
• Relative illuminance
Allows a relative measurement to a reference point to quantify a light input or an illuminance decrease.
• Evolution of illuminance according to weather conditions.
Storage of temporal evolution of illuminance for the follow-up of environment conditions.
• Cartography of illuminance – Spatial representation
Coloured representation according to levels obtained for printing of a report (on a computer such as PC).
• Uniformity
Calculation of the minimum / average ratio for determination of illuminance uniformity at workstation according to standards*.
• *Compatible with standards:
NF EN 12464-1 Lighting of workplaces (inside)
NF EN 12464-2 Lighting of workplaces (outside)
NF EN 12193 Lighting of sports facilities
|
|
|
|
MP 100
Applications
For low differential pressure
Measurement range
MP 100: from 0 to 1000 Pa • Resolution > 1 Pa
MP 101: from 0 to 1000 mmH2O• Resolution > 0.1 mmH2O (from 0 to ±200 H2O) and 1 mm H2O above
Version E: dispatched with a calibration certificate and a carrying case.
Version S: dispatched with an adjusting certificate and a carrying poach.
Functions * Micromanometer
Pressure, depression, differential pressure, manual auto-zero, function Hold, min/max values
|
|
|
|
|
MP 120
Applications
For the low differential pressure and air velocity with Pitot tube
Pressure and air velocity with Pitot tube
Measurement range * Pressure and air velocity with Pitot tube
Pressure: from 0 to ±1000 Pa • Resolution > 1 Pa
Air velocity: from 2 to 40 m/s • Resolution > 0.1m/s
Version E: dispatched with a calibration certificate and a carrying case.
Version S: dispatched with an adjusting certificate and a carrying poach.
Functions
* Micromanometer: pressure, negative pressure, differential pressure, manual auto-zero, selection of units (Pa, mmH2O. in Wc, min/max values
* Air velocity with Pitot: air velocity, manual auto-zero, selection of units (m/s and fpm), hold, min/max
|
|
|
|
|
MP 130
Manometer for Gas Network Leak Testing
• Pressure measurement, 130 mbar, 1.9 psi,
52 inH2O
• Selection of units
• Self-calibration
• Display of minimum and maximum value
• HOLD function
• Adjustable automatic shut-off
• Adjustable backlight
|
|
|
|
|
MP 115
Atmospheric pressure
• User-friendly
• Backlighted screen
• Indication of the pressure in mbar,
mmHg ou hPa
• Adjustment of the atmospheric pressure
based on the location (offset)
• Hold-min-max fucntion
|
|
|
|
|
SL 100
Solarimeter
The SL100 portable autonomous solarimeter
can measure solar irrigation for the control of photovoltaic and thermal installations on test
or on site.
• Measurement and spot check of solar power in W/m2
instantaneous
average
min./max. values
hold function
• Calculation of energetic exposure
in Wh/m²
during timed dataset
(Timed: duration of dataset is expressed
in DD/HH/MM/SS).
• Results (Wh/m2) saved when instrument is switched off.
• Easy to use, for immediate information
• Evaluation of generated electric power,
optimum orientation of solar panels, and
performances follow-up
• Choice and determination of thermal or
photovoltaic generators features
|
|
|
|
SL 200
Solarimeter
The SL200 portable autonomous solarimeter measures the solar irrigation for the control of photovoltaic and thermal installations on test or on site:
• Measurement and spot check of the solar irrigation in W/m²
(instantaneous, average, time-recording,
min/max values, hold function).
• Calculation of the energetic
exposure in Wh/m²
during the timed measures campaign.
• Storage and saving of average values
of power and updating the energetic
exposure calculation every minute.
• Recorded data can be read on the display,
and the graphic function allows a fast
interpretation of the measure file.
• Easy to use, for immediate information.
• Evaluation of the produced electric powers, optimum orientation of solar panels and performances follow-up.
• Analysis of sunshine on site, on short and long-term period.
• Choice and determination of the thermal or
photovoltaic generators features.
• Storage and saving of average values of
power; update of energetic exposure
calculation every minute.
• Easy use of data stored in memory.
• Reading and graphical approximation of data
by 24 hours via transfer data software .
|
|
|
|
SDA
Sound Level
The sound level meter SDA is reliable, easy to use and in accordance with metrology requirements. SDA can measure:
• Sound-pressure level
• Sound-pressure level LA
as per two weighting times FAST or SLOW
• To be used for stable or slightly
fluctuating sound sources.
• Sound-pressure level LA unit is dBA and
LAmax and LAmin values are saved.
|
|
|
|
DB 100
Automatic Check of Sound Level Meter
DB 100 sound level meter is reliable, easy to use and in accordance with metrology requirements. DB100 can measure:
• Sound-pressure level
• Time averaged or equivalent continuous
sound pressure level
• Sound-pressure level LA
as per two weighting times FAST or SLOW
• To be used for stable or slightly fluctuating
sound sources
• Sound-pressure level (LA ) unit is dBA and
LAmax and LAmin values are saved.
• Time averaged sound level LAeq.
• To be used for fluctuating sound sources.
• Time averaged sound level (LAeq) unit is dBA
with a programmable integration time in
minutes and seconds.
|
|
|
|
CTL 100
Automatic Check of Sound Level Meter
The automatic check consists in comparing sound level meter value with level produced by CTL100. The principle allows to periodically check sound level meter performance, especially the microphone performance which is the sensing element of the instrument.
The CTL100 can not replace an acoustic calibrator which must be used for sound level meter calibration.
|
|
|
|
DB 200
Integrating-averaging with storage function
FIVE DIFFERENT MEASUREMENT MODES:
• Mode 1: Conventional sound level meter
• Mode 2: Conventional sound level meter
with storage
• Mode 3: Conventional and integrating-
averaging sound level meter
• Mode 4: Integrating-averaging sound level
meter with storage
• Mode 5: Sound level meter “calculator”
of two sound sources
The DB200 sound level meter is supplied with LDB200 software for display data and measurement report printing.
|
|
|
|
DB 300
Sound level meter
Integrating Averaging and Stockage Analyzer
From simply taking sound level to real time frequency analysis, the DB 300 covers most of sound level applications.
Features:
• Accuracy : Class 1 - NF EN 61672-1 or
Class 2 - NF EN 61672-1
• Dynamic range from 20 to 137 dB
• X frequency weighting : A – C – Z
• Average sound level: Lxy
• Equivalent continuous level: Lxeq
• Peak pressure level: Lupk
• Noise exposure level : Lxe
• Real time analyzer by eights (octave)
bands values - 16 Hz to 16 kHz (DB300/1)
bands values - 31.5 Hz to 8 kHz (DB300/2)
• Value and graphic presentation
of NR comfort factor
|
|
|
|
|
CAL 200
Acoustic Calibrator
Standard noise source at high stability in level and in frequency, CAL200 acoustic calibrator is essentially dedicated to check microphone sensitivity and to calibrate sound level meters and acoustic measurement systems.
CAL200 sends a nominal acoustic pressure level of 94 dB at the frequency of 1000 Hz,;it corresponds to class 2 of NF EN 60942: 2003 and CEI 60942: 2003 standards.
Designed to remain compatible with microphones of different diameters, it is supplied with an adapter ring for a microphone of ½ inch diameter.
|
|
|
|
TR 100
Applications
For measure of Pt100 ohms temperature
Measurement range:
From -100 to +400°C • Resolution : 0,1°C (-100 to +400°C) 1°C above
Pt100 channels: 1 or 2, for TR100 or TR102
Version E: dispatched with a calibration certificate and a carrying case.
Version S: dispatched with an adjusting certificate and a carrying poach.
Functions * Pt100 Thermometer
Temperature, hold, min/max, Delta T (only TR102)
|
|
|
|
|
TR
150
RTD thermometer special agri-food sector
Same as the TR100 series but, in addition:
• IP65 protection with protective agri-food
sector grade cover
• Delta T (TR 152)
• Adjustable alarm
• Auto-Hold function
• HACCP compliant
|
|
|
|
|
TK 100
Applications
For the measure of thermocouple K, J or T temperature
Measurement Range
From -200 to +1300°C • Resolution : 0.1°C
1 or 2 thermocouple K, J or T channels (for TK100 or TK1002)
Version E: dispatched with a calibration certificate and a carrying case.
Version S: dispatched with an adjusting certificate and a carrying poach.
Functions * K Thermocouple Thermometer
Temperature, hold, min/max, Delta T (TK102)
|
|
|
|
|
TK
150
Thermocouple thermometer special
agri-food sector
Same as the TK100 series but, in addition:
• IP65 protection with protective agri-food sector
grade cover
• Delta T (TK 152)
• Adjustable alarm
• Auto-Hold function
• HACCP compliant
|
|
|
|
|
TN 100
Applications
For the measure of temperature with a coefficient probe for negative temperature
Measurement Range
From -40 to 100 °C • Resolution: 0.1°C
1 or 2 channels, according to model
|
|
|
|
|
TN 150
CTN thermometer special agri-food sector
Same as the TN100 series but, in addition:
• IP65 protection with protective agri-food sector
grade cover
• Delta T (TN 152)
• Adjustable alarm
• Auto-Hold function
• HACCP compliant
|
|
|
|
|
LV 101, LV 107, LV 110
Applications
For measure of air velocity, air flow and temperature
With remote vane probe, fixed to the instrument, Ø 100 mm (LV 110), Ø 70 mm (LV 107)
or Ø 14 mm (LV 101).
Measurement range
• LV 101
Air velocity (m/s, fpm, km/h): from 0.8 to
40 m/s • Resolution: 0.1; 155 to 7800 fpm
• LV 107
Air velocity (m/s, fpm, km/h): from 0.3 to 35
m/s • Resolution: 0.1; 60 to 6900 fpm
• LV 110
Air velocity (m/s, fpm, km/h): from 0.25 to 35
m/s • Resolution: 0.01 (<3 m/s), 0.1 above;
50 to 6900 fpm
All models
Temperature (°C/F): from -20 to +80°C
Resolution: 0.1°C
Air flow (m³/h, cfm, l/s, m³/s): from 0 to
99999 m³/h
Resolution: 1 m³/h
Air flow with cones (Ø100 mm vane only) :
from 0 to 99999 m³/h
Resolution: 1 m³/h
Version E: shipped with a calibration certificate
and a carrying case.
Version S: shipped with an adjusting certificate
and a carrying pouch. |
|
Functions
• Anemometer: air velocity, air flow and air flow with cone (with Ø100mm vane) (LV 110),
auto-average, selection of units (m/p, fpm, Km/h), hold, min/max
• Pt100 Thermometer (integrated in vane probe): Pt100 temperature, auto-average, choice
of units (°F or °C), hold, min/max values
|
|
|
|
|
VT 100
Applications
For measure of air velocity, air flow and temperature
Dispatched with a 8mm dia. hotwire probe and a calibration certificate.
Measurement range
Air velocity: from 0 to 30 m/s • Resolution: 0.01 (<3 m/s) or 0.1 above
Air flow with hotwire probe: 0 to 99999 m³/h • Resolution: 1 m³/h
Temperature: from -20 to +80°C • Resolution: 0.1°C
Version E: dispatched with a calibration certificate and a carrying case.
Version S: dispatched with an adjusting certificate and a carrying poach.
|
|
Functions
• Hotwire anemometer: air velocity, flow (direct measure to cones through openings), auto average, selection of units (m/s, fpm, Km/h, cu m/h, l/s, cfm, cu m/s) hold, min/max
• Pt100 thermometer (integrated in hotwire probe): temperature, selection of units (°F or °C),
hold, min/max |
|
|
|
|
HD 100
Applications
For measure of hygrometry and temperature
Dispatched with a hygrometry probe
Measurement range
Humidity: from 5 to 95 %RH • Resolution: 0.1 %RH
Temperature: from -20 to +70°C • Resolution: 0.1°C
Version E: dispatched with a calibration certificate and a carrying case.
Version S: dispatched with an adjusting certificate and a carrying poach.
Functions
Relative humidity, temperature, dew point, selection of units, hold, min/max
|
|
|
|
|
HD 150
Hygro-thermometer special agri-food sector
Same as the HD100 but, in addition:
• IP65 protection with protective agri-food sector
grade cover
• HACCP compliant
|
|
|
|
|
CT 100
Applications
For the measure of tachometry
CT 100 0: dispatched with optical tachometry probe and calibration certificate.
CT 100 C: dispatched with optical tachometry probe, contact adaptor and calibration certificate.
Measurement range
Optic probe (CT100 O): from 60 to 60000 RPM
• Resolution: 1 RPM
Contact probe (CT100 C): from 30 to 2000 m/min
• Resolution: 1 RPM
Version E: dispatched with a calibration certificate and a carrying case.
Version S: dispatched with an adjusting certificate and a carrying poach.
|
|
Functions
• Optical Tachometer: rotation speed, lineal speed, Hold function, min/max values, selection of units (tr/min and RPM)
• Contact Tachometer: rotation speed, lineal speed, Hold function, min/max values, selection of units (m/min, ft/min and in/min |
|
|
|
|
TM 200
Thermometer
Interchangeable measurement modules
1 instrument = more than 1 range
Wireless connection
Smart-plus system
Wireless or wired probes automatically recognized when connected to the instrument.
Thermocouple temperature module – 4 channels
Current / voltage module Option
Thermocouple probes – Large choice
Smart-plus Pt100 probes – Large choice
Wireless Pt100 probes – Large choice
|
|
|
|
|
MP 200
Manometer
Interchangeable measurement modules
Wireless connection
Smart-plus system
Probes automatically recognized when connected to the instrument.
MP 200 P – ± 500 Pa
MP 200 M – ± 2500 Pa
MP 200 G – ± 10,000 Pa
MP 200 H – ± 500 mBar
MP 200 HP – ± 2000 mBar Thermocouple temperature module – 4 channels
Current / voltage module
Pitot tubes – Large choice
Thermocouple temperature probes - Large choice Option
CO / Temperature probe Option
|
|
|
|
|
VT 200
Thermo-Anemometer
Interchangeable measurement modules
Wireless connection
Smart-plus system
Probes automatically recognized when connected to the instrument.
Wired or wireless Pt100 probes Option
Wireless vane probes – Ø 70 mm or Ø 100 mm Option
Current / voltage module
Thermocouple Module
Temperature Probes
Sensing elements
Hotwire
Ø 70 and 100 mm vane probes : Hall effect sensor, Ambient temperature : Pt100 class A.
Ø 14 mm vane probe : Proximity sensor, Ambient temperature : Pt100 class A.
Thermocouple probes
Pt100 probes Smart-plus
|
|
|
|
|
HD 200
Thermo-hygrometer
Interchangeable measurement modules
Wireless connection
Smart-plus system
Wireless or wired probes automatically recognized when connected to the instrument.
HD 200 STD – Current/voltage module – Standard Smart-plus probe
HD 200 HT – Current/voltage module – High temperature Smart-plus probe
Thermocouple temperature module – 4 channels
Wireless hygrometry probe – Large choice
Wired temperature probe – Large choice
Wireless temperature probe – Large choice
Hygrometer
Psychrometer
Surface Dew Point
WBGT index
|
|
|
|
|
AQ 200
Air quality
Interchangeables measurement modules
Wireless Connection
Smart-plus system
Wireless or wired probes automatically recognized when connected to the instrument.
Air quality
Climatic Conditions module
AIR QUALITY PROBES
Air Quality Probes
CO / Temperature
CO2 / Temperature
CO2 / Temperature / Hygrometry
Thermometer
Thermocouple Module
Current / voltage module
Multi-parameters recording
Memory : up to 8,000 measurement points or 50 datasets |
|
|
|
|
AMI 300
Multifunction
Interchangeable measurement modules
1 instrument = more than 1 range and 1 parameter available.
Wireless connection
Instrument / PC
Instrument / Probe
Smart-plus system
Probes automatically recognized when connected to the instrument.
Manometer
Pressure, Air Velocity and Airflow
Thermo-hygrometer
Hygrometer, Psychrometer, WBGT index
Air Quality
Climatic conditions module, Air Quality Probes
Current / voltage module
Thermometer
Thermocouple module, Pt100 and thermocouple temperature probes
|
|
|
|
Probes
|
|
|
Temperature probe NTC
for Class 100 portable instruments |
|
Temperature probes Pt100 and Pt1000
for Class 100 portable instruments |
|
Temperature probes Thermocouple K and T
for Class 100 – 200 – 300 portable instruments |
|
Measuring probes
for Class 200 - 300 portable instruments |
|
Interchangeable measurement modules
for Class 200 – 300 portable instruments |
|
Temperature probe Pt100 SMART PLUS
for Class 200 – 300 portable instruments |
|
|
|
CONES
Air flow cones
• Air flow measurement
• Suitable for the hot-wire and
vane Ø 100 mm anemometer
• Available in several dimensions
|
|
|
|
|
|