Class 110
CP111-12-13
CP114-15
TH110
HM110
TM110 CTV110   CP116 CO110
CO112
CR110 LR110
Class 210
CP210 TH210 TM210 CTV210     COT210
COT212
   
Class 310
New 2014
C310
CA310
CPE310
C310
CA310
C310
CA310
C310
CA310
CA310 C310
CA310
C310
CA310
   
Class 310
PROBES CLASS 310 TEMPERATURE HYGROMETRY CO AND CO2
Class 310
PROBES CLASS 310 AIR VELOCITY TEMPERATURE
Class 310
INTERCHANGEABLE BOARDS
Monostats
PST HST TST       CO2ST
COST
   
Accessories
DEBIMO BLADES - PITOT TUBE - CAST IRON FLANGE - STAINLESS STEEL FLANGE

COMPRESSION FITTING - STUFFING-BOX - HOSES - PROBES CLASS 310 TEMPERATURE HYGROMETRY CO AND CO2

PROBES CLASS 310 AIR VELOCITY TEMPERATURE


Class 110

CP111 CP112 CP113
Differential pressure transmitter type
CP111, CP112, CP113

• Ranges from -100/+100 Pa to -10000/+10000 Pa
(according to models)
• Configurable intermediary ranges
• 0-10 V or 4-20 mA output, active, power supply
24 Vac/Vdc (3-4 wires) or 4-20 mA output, passive loop,
power supply from 16 to 30 Vdc (2 wires)
• ABS V0 housing, IP65, with or without display
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system
• Solenoid valve for auto-calibration
(only on CP111 model)

CP114 CP115

Differential pressure transmitter type
CP114, CP115

• Ranges from -500/+500 mbar to -2000/+2000 mbar
(according to models)
• Configurable intermediary ranges
• 0-10 V or 4-20 mA output, active, power supply
24 Vac/Vdc (3-4 wires) or 4-20 mA output, passive
loop, power supply from 16 to 30 Vdc (2 wires)
• ABS V0 housing, IP65, with or without display
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system

CP116

Atmospheric pressure transmitter type CP116

• Measuring range from 800 to 1100 hPa
• Indication of the pressure in mbar, mmHG ou hPa
• 0-10 V or 4-20 mA output, active, power supply
24 Vac/Vdc (3-4 wires) or 4-20 mA output, passive
loop, power supply from 16 to 30 Vdc (2 wires)
• ABS V0 housing, IP65, with or without display
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system



CTV110



Temperature and air velocity transmitter type CTV110.

• Measuring range from 0 to 30 m/s and from 0 to 50 °C
• 0-10 V or 4-20 mA output, active, power supply
24 Vac/Vdc (3-4 wires)
• ABS V0 housing, IP65, with or without display
• Alternating display of air velocity and temperature
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system





TH110

Humidity and temperature transmitter type TH100.

• Measuring range from 5 to 95%RH and from
0 to 50 °C (ambient model) or from -20 to +80 °C
(duct or remote model)
• 0-10 V output, active, power supply 24 Vac/Vdc
(3-4 wires) or 4-20 mA output, passive loop,
power supply from 16 to 30 Vdc (2 wires)
• ABS V0 housing IP65 (duct or remote model)
or IP20 (ambient model), with or without display
• Alternating display of humidity and temperature.
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system

HM110

Humidity transmitter type HM110.

• Measuring range from 5 to 95%RH
• 0-10 V output, active, power supply 24 Vac/Vdc
(3-4 wires) or 4-20 mA output, passive loop,
power supply from 16 to 30 Vdc (2 wires)
• ABS V0 housing IP65 (duct or remote model)
or IP20 (ambient model), with or without display
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system

TM110


Temperature transmitter type TM110.

• Range from 0 to 50 °C (ambient model), from
-20 to +80 °C (duct model) and from -100 to 400 °C
(model with Pt100 or NTC terminal block)
• 0-10 V output, active, power supply 24 Vac/Vdc
(3-4 wires) or 4-20 mA output, passive loop,
power supply from 16 to 30 Vdc (2 wires)
• ABS V0 housing, IP65 (remote and duct models) or
IP20 (ambient model), with or without display
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system




CO110

CO transmitter type CO110.

• Range from 0 to 500 ppm
• 0-10 V active output, power supply 24 Vac/Vdc
(3-4 wires) or 4-20 mA output, passive loop,
power supply from 16 to 30 Vdc (2 wires)
• ABS V0 housing, IP65 (depending on model),
with or without display
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system

CO112

CO2 transmitter type CO112.

• Range from 0 to 5000 ppm
• 0-10 V output, active, power supply 24 Vac/Vdc
(3-4 wires) or 4-20 mA output, passive loop,
power supply from 16 to 30 Vdc (2 wires)
• ABS V0 housing, IP65 (depending on model),
with or without display
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system


CR110



Solar radiation transmitter type CR110.

• Range from 0 to 1500 W/m²
• 0-10 V active output, power supply 24 Vac/Vdc
(3-4 wires) or 4-20 mA output, passive loop,
power supply from 16 to 30 Vdc (2 wires)
• ABS V0 housing, with or without display
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system









LR110



Light transmitter type LR110.

• Range from 0 to 10000 lux
• 0-10 V active output, power supply 24 Vac/Vdc
(3-4 wires) or 4-20 mA output, passive loop,
power supply from 16 to 30 Vdc (2 wires)
• ABS V0 IP65 housing, with or without display
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system











Class 210


CP210

Temperature and differential pressure transmitter

• Range from -100/+100 Pa to -2000/+2000 mbar
(according to, see "Part number")
Input Pt100 on terminal block for temperature
measurement, range from -100 to +400 °C
(probes as option)
• Configurable intermediate ranges
• 4 wires analogue output 0-5/10 V or 0/4-20 mA
• Power supply 24 Vdc/Vac or 115/230 Vac
• Trend indicator
• ABS V0 housing, IP65, with or without display
• "¼ turn" system mounting with wall-mount plate
• Solenoid valve for auto-calibration (only on
CP211 and CP212 models)


 


CTV210


Air velocity and temperature transmitter

• Configurable ranges from 0 to 30 m/s (model
with hot wire probe) and from 0 to 5 m/s
(model with omnidirectional probe)
• Configurable range from 0 to 50 °C in temperature
• Airflow function
• 4 wires analogue output 0-5/10 V or 0/4-20 mA
• Power supply 24 Vdc/Vac or 115/230 Vac
• Trend indicator
• ABS V0 IP65 housing, with or without display
• "¼ turn" system mounting with wall-mount plate




 


TH210

Humidity and temperature transmitter

• Configurable measuring ranges from 5 to 95%HR
and from -40 to +180 °C
(according the type of probe)
• Functions : relative and absolute humidity,
dew point, wet and dry temperature and enthalpy
• Stainless steel or polycarbonate probe
• 4 wires analogue output 0-5/10 V or 0/4-20 mA
• Power supply 24 Vdc/Vac or 115/230 Vac
• Trend indicator
• ABS V0 IP65 housing, with or without display
• "¼ turn" system mounting with wall-mount plate



 


TM210


Temperature transmitter

• Configurable ranges from 0 to 50 °C
(ambient model) and from -100 to 400 °C
(model with terminal block)
• Possibility of a second remote probe on terminal block
• Display of the minimum and maximum values
and trend indicator
• 4 wires analogue outputs 0-5/10 V or 0/4-20 mA
• Alimentation 24 Vdc/Vac ou 115/230 Vac
• ABS V0 IP65 housing, with or without display
• "¼ turn" system mounting with wall-mount plate




 


COT210

Humidity and temperature transmitter

• Configurable measuring ranges from 5 to 95%HR
and from -40 to +180 °C
(according the type of probe)
• Functions : relative and absolute humidity,
dew point, wet and dry temperature and enthalpy
• Stainless steel or polycarbonate probe
• 4 wires analogue output 0-5/10 V or 0/4-20 mA
• Power supply 24 Vdc/Vac or 115/230 Vac
• Trend indicator
• ABS V0 IP65 housing, with or without display
• "¼ turn" system mounting with wall-mount plate



 


COT212


CO2 and temperature transmitter

• Configurable ranges from 0 to 20000 ppm
and from 0 to 50 °
• 4 wires analogue output 0-5/10 V or 0/4-20 mA
• Power supply 24 Vdc/Vac or 115/230 Vac
• Trend indicator
• ABS V0 IP65 housing, with or without display
• "¼ turn" system mounting with wall-mount plate





Class 310


C 310
Multifunction transmitter


• 2 inputs for interchangeable probes
• 1 location for interchangeable SPI-2 board
• Simultaneous display of 1 to 4 parameters
• Trend indicator
• 4 visual (dual-color LEDs) and audible alarms
• 2 analogue outputs (4 wires) 0/5-10 V or
0/4-20 mA, 2 additional outputs (optional)
• 4-relay board (optional)
• 24 Vdc/Vac or 115/230 Vac power supply
• Outputs diagnostic
• Ethernet communication (optional)
• MODBUS network RS485 system (optional)
• ABS housing with stainless steel front, IP65,
with or without backlit graphic display
• "¼ turn" system mounting with wall-mount plate


CA 310
Large display multifunction transmitter


• 1 input for interchangeable probe
• 1 location for SPI-2 or MVA interchangeable board
• Alternating display of 1 to 3 parameters
• 3 audible and visual (dual-color LEDs) alarms
• 3 analogue outputs (4 wires) 0/5-10 V or 0/4-20 mA
• 3 reverse relays 3 A/230 Vac
• 24 Vdc/Vac or 115/230 Vac power supply
• Outputs diagnostic
• Ethernet communication (optional)
• MODBUS network RS485 system (optional)
• ABS V0 swivelling housing
• Large display : 50 x 190 mm


CPE 310-S
Flush-mount multifunction pressure transmitter




• Measuring range : from 0/+10 Pa to
00/+10 000 Pa (probe dependent)
• Measuring Ranges from -100 to +100 Pa1
• Input for interchangeable probe (Class 310)
• Alternating display of 1 to 3 parameters
• Front face calibration
• Configurable intermediate and centre zero ranges
• 3 audible and visual alarms
• Front face keypad allowing to configure the
transmitter and acknowledge the alarm
• 3 analogue outputs 0-5/10 V or 0/4-20 mA
• High resolution in pressure on model -100/+100 Pa
(ex : 0.1 Pa) (optional)
• Outputs diagnostic
• MODBUS network RS485 system (optional)
• Front face made of brushed stainless steel with
electroluminescent display







Monostats

HST


Hygrostats

• Measuring range from de 5 to 95%HR and from
0 to 50 °C (ambient model) or from -20 to +80 °C
(duct and remote model)
• RCR relay output 3A/230 Vac, power supply 24 Vac/Vdc
• Visual and audible alarm, red led in front
• ABS V0 IP65 housing (duct and remote model)
or IP20 (ambient model)
• Alternating display of humidity and temperature.
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system




PST

Manostats

• Range from -100/+100 Pa to -2000/+2000 mbar
(according to model)
• RCR relay output 3A/230Vac. Power supply 24Vac/Vdc.
• Visual and audible alarm, red led in front
• ABS V0 IP65 housing
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system
• Solenoid valve for auto-calibration (only on PST11 model)



TST

Thermostats

• Range from 0 to 50 °C (ambient model), from
-20 to +80 °C (duct model) and from -100 to 400 °C
(modèle avec bornier Pt100 ou CTN)
• RCR relay output 3A/230Vac. Power supply 24Vac/Vdc.
• Visual and audible alarm, red led in front
• ABS V0 IP65 housing (duct and remote model)
or IP20 (ambient model)
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system


CO2ST

CO2 stats

• Range from 0 to 5000 ppm
• RCR relay output 3A/230Vac. Power supply 24Vac/Vdc.
• Visual and audible alarm, red led in front
• ABS V0 IP65 housing (according to the model)

• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system


COST

CO stats

• Range from 0 to 500 ppm
• RCR relay output 3A/230Vac. Power supply 24Vac/Vdc.
• Visual and audible alarm, red led in front
• ABS V0 IP65 housing (according to the model)
• "¼ turn" system mounting with wall-mount plate
• Housing with simplified mounting system




Accessories

DEBIMO
Applications : air supply systems in laboratories, air conditioning systems, air flow test rigs, fume extraction and exhaust systems, vacuum cleaning systems.

KIMO DEBIMO flow measuring blades are a simple and cost effective method of providing permanent air flow measurement in rectangular or circular ducts. When used with a KIMO differential pressure device (pressure, transmitter, electronic micromanometer, liquid column manometer, differential pressure switch, ...).
DEBIMO air flow measuring blades ensure accurate indication, control or recording of air flow velocity and volume.
Permit velocity measurements from 3 to 100 m/s (9 Pa to 10000 Pa).
Airfoil section limiting differential heads (<3%) and turbulences.
Distribution of the measurement apertures on the airfoil permitting the medium air flow control (average of the differential pressures).


PITOT TUBE

KIMO offers a wide range of high-quality and accurate Pitot tubes, as per the AFNOR NFX 10-112 norm.
Accuracy : More than 1 %, for a ± 10 ° alignment to the fluid flow.

Pitot tubes Type L
Pitot tube with ellipsoidal head. An intake for total pressure and 6 holes for static pressure. Body made of stainless steel.
Pitot tubes Type L with TCK
Pitot tube with ellipsoidal head. An intake for total pressure and 6 holes for static pressure. Sheated thermocouple K probe integrated, with connection cable length 1,5 m. Body made of stainless steel.

Length of the Pitot tubes Type L

Ø 3 mm : 100 mm, 200 mm and 300 mm
Ø 6 mm : 300 mm, 500 mm and 800 mm
Ø 8 mm : 1000 mm and 1250 mm
Ø 12 mm : 1500 mm and 2000 mm
Ø 14 mm : 2500 mm and 3000 mm

PITOT
TYPE
L

PITOT
TYPE
S

CAST IRON FLANGE

BF-12-F
: Cast iron mounting brackets for
Pitot tubes Ø 12 mm
BF-14-F : Cast iron mounting brackets for
Pitot tubes Ø 14 mm
BF-28-F : Cast iron mounting brackets for
Pitot tubes S type Ø 28 m

 

STAINLESS STEEL CLAMP

KI-BF
: Clamp for temperature transmitter Ø 6 or 8 mm.
KI-BF-6 : Stainless steel clamp for Pitot tube Ø 3 and 6 mm.
KI-BF-8 : Stainless steel clamp for Pitot tube Ø 8 mm.


SLIDING CONNECTION

Airtight sliding connection
The sliding connection guarantees an airtight connection of a temperature sensor by the means of a stainless steel or Teflon clamp ring, crimped when being tightened.
 


STUFFING-BOX

For fixed-station Pitot tubes installation. Diameter 3, 6 or 8 mm.

 
 
TUBES

Clear tube Ø 5 x 8
For permanent installation (m/l or 25m).
Silicone tube Ø 4 x 7
Black or white, for test instruments (m/l or 25 m).

Probes / Boards for 310 Series

SERIES C310 PROBES
Temperature, hygrometry, CO and CO2 probes
for class 310 transmitters



SHSI
Stainless steel interchangeable hygrometry and ambient
temperature probe with stainless steel filter. Standard
mounting probe 120 mm length with hermetic connector
1/4 de tour.
SHDI-150
Stainless steel interchangeable hygrometry and ambient
temperature probe with stainless steel filter. Remote
probe 150 mm length, 13 mm diameter. White silicone
cable 2 m length with hermetic connector.
SHDP-150 and 300
Polycarbonate interchangeable hygrometry and ambient
temperature probe with stainless steel filter. Remote
probe 150 mm and 300 mm length, 13 mm diameter.
White silicone cable 2 m length with hermetic connector.
SCCO
ABS V0 interchangeable CO and temperature probe.
Remote probe 160 mm length, 26 mm diameter. White
PVC cable 2 m length with hermetic connector.
SCO2
ABS V0 interchangeable CO2 and temperature probe.
Remote probe 160 mm length, 26 mm diameter. White
PVC cable 2 m length with hermetic connector.
STD-13
Interchangeable Pt100 1/3 DIN temperature probe for
general use, contact tip 6 mm diameter, 150 mm length,
IP65. Grey silicone cable 2 m length with hermetic
connector.









SERIES C310 PROBES
Air velocity and temperature probes for class 310
transmitters



SVH-14
Interchangeable remote air velocity and temperature
probe with Ø 14 mm vane, 300 mm length, white PVC
cable 2 m length with hermetic connector.
SVH-70
Interchangeable remote air velocity and temperature
probe with Ø 70 mm vane, 300 mm length, white PVC
cable 2 m length with hermetic connector.
SVH-100
Interchangeable remote air velocity and temperature
probe with Ø 100 mm vane, 300 mm length, white PVC
cable 2 m length with hermetic connector.

SVS

Interchangeable stainless steel hotwire remote probe
of air velocity and temperature 300 mm length, 8 mm
diameter, white PVC cable 2 m length with hermetic
connector.
SVO
Interchangeable stainless steel omnidirectional remote
probe of air velocity and temperature 300 mm length,
8 mm diameter, white PVC cable 2 m length with
hermetic connector. Supplied with transport case
and tripod.










Interchangeable Boards for Series
C310 and CA310 Transmitters

INTERCHANGEABLE PRESSURE BOARDS
FOR C310 AND CA310


Interchangeable board with solenoid valve and
Thermocouple K connector for C310 transmitters.
Supplied with pressure connectors, silicone tube
and adjustment certificate.

SPI2-100 = -100 / +100 Pa
SPI2-500 = -500 / +500 Pa
SPI2-1000 = -1000 / +1000 Pa
SPI2-10000 = -10000 / +10000 Pa


INTERCHANGEABLE ATMOSPHERIC PRESSURE
BOARDS FOR C310 AND CA310

SPI2-ATMO

Interchangeable board for C310 and CA310
transmitters, range from 800-1100 hPa.
Supplied with pressure connection, silicone tube
and adjustment certificate.